Graywater turbidity removal by coagulation/ flocculation/ decantation us-ing response surface methodology

×

Error message

User warning: The following theme is missing from the file system: journalijdr. For information about how to fix this, see the documentation page. in _drupal_trigger_error_with_delayed_logging() (line 1138 of /home2/journalijdr/public_html/includes/bootstrap.inc).

International Journal of Development Research

Volume: 
12
Article ID: 
24823
9 pages
Research Article

Graywater turbidity removal by coagulation/ flocculation/ decantation us-ing response surface methodology

Mayk Ernando Brito de Barros Miranda, Edson Nunes Lemes Júnior, Marcelo Mendes Pedroza, Fábio Ribeiro da Silva Júnior, Aymara Gracielly Nogueira Colen, Vanilcia Clementina de Oliveira Marto, Ana Karla Carvalho Aragão de Faria and Isabella Juwer Nascimento

Abstract: 

The gray waters from washing machines are the ones that show the easiest treatment due to their physical, chemical, and microbiological characteristics. This study characterized the samples of gray water generated in a laundry in Palmas-TO and applied the coagulation/ flocculation/ decantation test, analyzing the removal of turbidity to determine the statistical model that represents the efficiency of the adopted process. Bench tests were carried out simulating a gray water treatment process: coagulation, flocculation, sedimentation, and filtration in a sand filter using the Jar-Test equipment with the use of aluminum sulfate coagulant, and the factorial plans were also made: fractional factorial design (FFD) and central rotational composite design (CRCD). For the characterization of the samples, the following results were obtained: pH (9.2), temperature (25ºC), turbidity (112uT), COD (200 mg / L), and alkalinity (241 mg / L). In the DFF process, turbidity responses between 7.8 uT and 28.1 uT are observed, and according to the Pareto graph, the greatest effects on the sample's turbidity result were the coagulant dosage variables (9.45) and sedimentation time (-10.70). In the CRCD process, the turbidity result between 5.2 and 26.1 uT was obtained through a regression model and according to the Pareto graph, the two variables X1 Dosage (mg / L) and X2 Sedimentation Time (min) showed considerable significance for the response. Through the analysis of variance, the R² coefficient reached by the regression was 0.9641, showing a good fit of the model. The results determined the statistical model that represents the removal of gray water turbidity through the coagulation/flocculation/decantation process.

DOI: 
https://doi.org/10.37118/ijdr.24823.07.2022
Download PDF: